Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Suzhou Ronty Technology Co., Ltd.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Miss Miranda
  • 电话:86-512-67250845
  • 传真:86--67250844
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > St9000 Defibrillator with 6.5 Inches TFT
St9000 Defibrillator with 6.5 Inches TFT
单价 $400.00 / Piece对比
询价 暂无
浏览 210
发货 Chinaanhuisuzhou
库存 400Piece
过期 长期有效
更新 2020-05-16 20:56
 
详细信息
Product Name: St9000 Defibrillator with 6.5 Inches TFT Model NO.: ST9000 Display Resolution: 800 X 600 Pixels Trademark: Ronty Transport Package: Standard Export Specification: plastic and metal Origin: China Product Description Specifications:DefibrillatorEnergy Select:External: 2, 5, 7, 10, 20, 30, 50,70, 100, 150, 200, 300, 360 J.Charge Time:< 7 seconds @ 360 J (with a Smart Pak Plus battery after 15discharges).< 9 seconds @ 360 J (with a Super Pac battery after 15 discharges).< 15 seconds @ 360 J (no battery, 90% AC mains voltage)Charge Indicator: Audible and graphic.Output: Adult paddles, pediatric adapter and multipurpose hands-free adapter available.Synchronizer: Delivers energy within 60 msec.Disarm: Front panel switch.Monitor/DisplayInput: 3-lead, 5-lead, patient cable, paddles, or multi-purpose hands-free adapter.Size: 6.5 inches (16.5 cm) diagonal, non-fade.Type: color (TFT)Display Resolution: 800 x 600 pixels.Sweep Speed: 12.5mm/s,25mm/s,50mm/sLead Selections: Paddles(Pads), I, II, III, AVR, AVL, AVF, V.Heart Rate Meter: 20 to 300 BPM.Heart Rate Alarms: User-selectable.Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv and auto-ranging.Aspect Ratio: 0.5, 0.1, 0.4, 0.8, 1.6, respectively.ECG Output: 1 V/mV.AlarmsHeart Rate, BP, SpO2, Resp & Temp Alarm:Audible: 5 pulse, 800 tone, with a PW of 150 m sec, a PRI of 225m sec, and a repetition interval of 10 seconds.Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of thedisplay and is 0.4"high and 0.28 to 0.840" wide depending on number of digits in the heart rate. Color is amber,black, white, or whatever the color the display text is.Lead Fault Alarm:Audible: 3 pulse, 500 Hz, triplet tone with a PW of 200 m sec, aPRI of 310 msec. When the HR alarm is set orthe pacer is on, the lead fault one repeats at a repetition interval of 20 seconds.Visual: Lead Fault condition causes a "LEAD FAULT" message to be displayed on the trace along with a dashedline the width of the trace. The text is 0.18" high and is the color of the display text. The dashed line is 5" long, thewidth of the display. The signal is not modulated.Physiological Alarms (SpO2):Audible: See Heart Rate AlarmVisual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber, white or the same asthe display colored text.Mute Duration: 90 seconds.